92 research outputs found

    Mid-term functional outcome of a total arthroplasty of the first metatarsophalangeal joint

    Get PDF
    Arthroplasty of the first metatarsophalangeal joint is an alternative treatment option for end-stage hallux rigidus to the current gold standard of arthrodesis. The aim of this study was to investigate the mid-term functional outcome of an anatomically shaped prosthesis for the first metatarsophalangeal joint using pedobarography.; Ten patients (12 affected feet; age at surgery: 62.1 (SD: 7.2) years) were investigated preoperatively and 52 (SD: 3) months postoperatively using pedobarography (EMED, novel GmbH, Munich, Germany). Two patients were excluded at follow-up because their prosthesis was converted to an arthrodesis. Peak force and plantar pressure under the five metatarsal heads and the hallux were analyzed and correlated with the clinical outcome (pain, American Orthopaedic Foot and Ankle Society forefoot score and radiographic maximum first metatarsophalangeal dorsiflexion). Differences between pre- and postoperative data were analyzed using paired t-tests (alpha=0.05).; Postoperatively, forefoot peak forces under the fourth (+40.9%; P=0.018) and fifth metatarsal (+54.9%; P=0.037) and plantar pressures under the fifth metatarsal (+38.7%; P=0.027) increased significantly, while peak plantar pressures and forces under the hindfoot, medial forefoot and hallux did not change. While maximum passive dorsiflexion was not significantly greater at the 4-year follow-up compared to preoperatively, overall greater passive dorsiflexion was associated with higher first metatarsal peak pressure.; Despite of patients reporting less pain, the functional results indicate an altered and potentially non-physiological postoperative gait pattern with a lateralization of the load during walking, especially in patients with limited passive dorsiflexion

    Measuring joint kinematics of treadmill walking and running: Comparison between an inertial sensor based system and a camera-based system

    Get PDF
    Inertial sensor systems are becoming increasingly popular for gait analysis because their use is simple and time efficient. This study aimed to compare joint kinematics measured by the inertial sensor system RehaGait® with those of an optoelectronic system (Vicon®) for treadmill walking and running. Additionally, the test re-test repeatability of kinematic waveforms and discrete parameters for the RehaGait® was investigated. Twenty healthy runners participated in this study. Inertial sensors and reflective markers (PlugIn Gait) were attached according to respective guidelines. The two systems were started manually at the same time. Twenty consecutive strides for walking and running were recorded and each software calculated sagittal plane ankle, knee and hip kinematics. Measurements were repeated after 20min. Ensemble means were analyzed calculating coefficients of multiple correlation for waveforms and root mean square errors (RMSE) for waveforms and discrete parameters. After correcting the offset between waveforms, the two systems/models showed good agreement with coefficients of multiple correlation above 0.950 for walking and running. RMSE of the waveforms were below 5° for walking and below 8° for running. RMSE for ranges of motion were between 4° and 9° for walking and running. Repeatability analysis of waveforms showed very good to excellent coefficients of multiple correlation (>0.937) and RMSE of 3° for walking and 3-7° for running. These results indicate that in healthy subjects sagittal plane joint kinematics measured with the RehaGait® are comparable to those using a Vicon® system/model and that the measured kinematics have a good repeatability, especially for walking

    Inertial Sensor-Based Gait and Attractor Analysis as Clinical Measurement Tool: Functionality and Sensitivity in Healthy Subjects and Patients With Symptomatic Lumbar Spinal Stenosis

    Get PDF
    Objective: To determine if the attractor for acceleration gait data is similar among healthy persons defining a reference attractor; if exercise-induced changes in the attractor in patients with symptomatic lumbar spinal stenosis (sLSS) are greater than in healthy persons; and if the exercise-induced changes in the attractor are affected by surgical treatment.Methods: Twenty-four healthy subjects and 19 patients with sLSS completed a 6-min walk test (6MWT) on a 30-m walkway. Gait data were collected using inertial sensors (RehaGait®;) capturing 3-dimensional foot accelerations. Attractor analysis was used to quantify changes in low-pass filtered acceleration pattern (δM) and variability (δD) and their combination as attractor-based index (δF = δM* δD) between the first and last 30 m of walking. These parameters were compared within healthy persons and patients with sLSS (preoperatively and 10 weeks and 12 months postoperatively) and between healthy persons and patients with sLSS. The variability in the attractor pattern among healthy persons was assessed as the standard deviation of the individual attractors.Results: The attractor pattern differed greatly among healthy persons. The variability in the attractor between subjects was about three times higher than the variability around the attractor within subject. The change in gait pattern and variability during the 6MWT did not differ significantly in patients with sLSS between baseline and follow-up but differed significantly compared to healthy persons.Discussion: The attractor for acceleration data varied largely among healthy subjects, and hence a reference attractor could not be generated. Moreover, the change in the attractor and its variability during the 6MWT differed between patients and elderly healthy persons but not between repeated assessments. Hence, the attractor based on low-pass filtered signals as used in this study may reflect pathology specific differences in gait characteristics but does not appear to be sufficiently sensitive to serve as outcome parameter of decompression surgery in patients with sLSS

    Reduction in ulnar pressure distribution when walking with forearm crutches with a novel cuff design: Cross-sectional intervention study on the biomechanical efficacy of an ulnar recess

    Get PDF
    Walking with crutches is an effective way of reducing the load on the lower extremity and is often indicated after injury or surgery. However, walking with forearm crutches with conventional cuffs can trigger symptoms including tenosynovitis in the biceps tendon, ulnar neuropraxia at the wrist, pain, or skin hematoma. The purpose of this study was to test the hypothesis that a crutch cuff design with an ulnar recess reduces ulnar pressure during walking with forearm crutches. The pressure distribution between the forearm and crutch cuff was measured in 15 healthy participants for crutch walking with conventional and novel cuffs, respectively. Relative peak pressure in the proximal medial region compared to the overall peak pressure was reduced by 8.6% when walking with crutches with the novel cuff design compared to conventional cuffs (p < 0.001). Relative peak pressure in the distal intermediate and lateral regions were increased by 3.3% and 3.7% for the novel compared with conventional cuffs, respectively (p < 0.001 for both). Hence, the novel crutch cuffs shifted regions of high pressure away from the proximal ulnar region towards more distal regions that are covered by more soft tissue

    The effect of different running shoes on treadmill running mechanics and muscle activity assessed using statistical parametric mapping (SPM)

    Get PDF
    Differences in joint mechanics between running shoes are commonly assessed using discrete parameters, yet statistically significant differences in these parameters between shoes are often scarce with small effect sizes. Statistical parametric mapping (SPM) has been suggested as suitable method for analyzing one-dimensional data such as kinematic, kinetic or muscle intensity time series.; The purpose of this study was to determine differences in treadmill running mechanics between novel running shoes using SPM.; Joint kinematics, muscle activity and ground reaction force were assessed in 19 rearfoot runners in their own shoes and in two test shoes during treadmill running (test shoe 1: 13 distinct rubber elements in the outer sole, springboard within EVA midsole with posterior elements shifted anteriorly by approximately 1.5 cm; test shoe 2: 17 distinct EVA elements with conventional heel geometry). Joint kinematics were measured using an inertial sensor system, and ground reaction force was measured using an instrumented treadmill.; SPM analysis with repeated measures ANOVA revealed significant reductions in the ankle angle and in tibialis anterior, peroneus longus, vastus medialis and lateralis muscle activity during weight acceptance and in peroneus longus muscle activity during early and late swing and in semitendinosus muscle activity during late swing for the test shoes. Significant differences in muscle activity were observed in the interval of the main activity of the respective muscle. SPM on individual data revealed statistically significant and relevant within-subject differences between conditions in kinematic, muscle activity and ground reaction force patterns.; Inertial sensor systems and SPM may provide an efficient way of detecting changes in joint mechanics between running shoes within runners. Detecting within-subject differences in running mechanics between conditions not only requires statistical criteria but also criteria on the relevance of the magnitude of differences

    Assessing in vivo articular cartilage mechanosensitivity as outcome of high tibial osteotomy in patients with medial compartment osteoarthritis: experimental protocol

    Get PDF
    Objective To propose an experimental protocol for using high tibial osteotomy (HTO) as a model for studying in vivo biological effects of large permanent changes in ambulatory load. Design This study is a prospective multimodal (clinical, biomechanical, biological) data collection without randomization. The study will examine a cohort of 40 patients with medial compartment knee OA undergoing opening wedge HTO. Experimental protocol Before planned HTO, patients will be clinically assessed (including mechanical axis measurement from radiographs) and complete questionnaires on physical function. Patients will complete a walking stress test with blood sampling (30 min walking, 5.5 h sitting), and undergo gait analysis. Six weeks after HTO (at the time of full weight bearing), the mechanical axis will be measured from radiographs. Patients will complete the questionnaires and a walking stress test with blood sampling, and undergo gait analysis 6 months after HTO. The peak external knee adduction moment, knee external knee adduction moment impulse and peak external knee flexion moment will be used as surrogates of ambulatory load. Load-induced changes in cartilage biomarkers will be used as surrogates of metabolic changes in response to ambulatory load. At the 12-month follow-up, subjects will complete the questionnaires. Conclusion The results of this study can be considered as proof-of-concept of a potential diagnostic test (walking stress test) for cartilage degeneration and its prognostic value. A direct relationship between ambulatory load and cartilage metabolism assessed as degradation to synthesis ratio would allow developing novel load-modifying interventions and evaluating the efficacy of existing interventions

    Validity and reliability of a portable gait analysis system for measuring spatiotemporal gait characteristics: comparison to an instrumented treadmill

    Get PDF
    Gait analysis serves as an important tool for clinicians and other health professionals to assess gait patterns related to functional limitations due to neurological or orthopedic conditions. The purpose of this study was to assess the validity of a body-worn inertial sensor system (RehaGait®) for measuring spatiotemporal gait characteristics compared to a stationary treadmill (Zebris) and the reliability of both systems at different walking speeds and slopes.; Gait analysis was performed during treadmill walking at different speeds (habitual walking speed (normal speed); 15 % above normal walking speed; 15 % below normal walking speed) and slopes (0 % slope; 15 % slope) in 22 healthy participants twice 1 week apart. Walking speed, stride length, cadence and stride time were computed from the inertial sensor system and the stationary treadmill and compared using repeated measures analysis of variance. Effect sizes of differences between systems were assessed using Cohen's d, and limits of agreement and systematic bias were computed.; The RehaGait® system slightly overestimated stride length (+2.7 %) and stride time (+0.8 %) and underestimate cadence (-1.5 %) with small effect sizes for all speeds and slopes (Cohen's d ≤ 0.44) except slow speed at 15 % slope (Cohen's d > 0.80). Walking speed obtained with the RehaGait® system closely matched the speed set on the treadmill tachometer. Intraclass correlation coefficients (ICC) were excellent for speed, cadence and stride time and for stride length at normal and fast speed at 0 % slope (ICC: .91-1.00). Good ICC values were found for stride length at slow speed at 0 % slope and all speeds at 15 % slope (ICC: .73-.90). Both devices had excellent reliability for most gait characteristics (ICC: .91-1.00) except good reliability for the RehaGait® for stride length at normal and fast speed at 0 % slope and at slow speed at 15 % slope (ICC: .80-.87).; Larger limits of agreement for walking at 15 % slope suggests that uphill walking may influence the reliability of the RehaGait® system. The RehaGait® is a valid and reliable tool for measuring spatiotemporal gait characteristics during level and inclined treadmill walking

    Scope and Limits of Teriparatide Use in Delayed and Nonunions: A Case Series

    Get PDF
    Nonunion is known to occur in up to 10% of all bone fractures. Until recently, the treatment options considered in cases of delayed union and nonunion focused on revision surgery and improvement of local healing. Lately, teriparatide has been introduced as an osteoanabolic factor that induces fracture healing in cases with delayed or nonunions. We report on a series of five cases of delayed and nonunions treated with teriparatide: delayed unions of an atypical femoral fracture, of a multifragmentary clavicle fracture, and of a periprosthetic humeral fracture; nonunion of a tibial and fibular fracture; and infected nonunion of a tibial and fibular fracture. Based on this series, the indications and limits of application of teriparatide in cases of impaired fracture healing are discussed. Due to the "off-label" character of this application, informed consent, and cost coverage from the healthcare insurance must be obtained prior to treatment. In our experience and according to the limited existing literature, teriparatide is a safe feasible treatment in cases of delayed and nonunions with a reasonable need of resources. While adequate biomechanical stability remains the cornerstone of fracture healing, as well as healing of nonunions, teriparatide could help avoid repetitive surgeries, especially in atrophic delayed and nonunions, as well as in patients with impaired fracture healing undergoing bisphosphonate therapy. There is an urgent need for widely accepted definitions, standardized protocols, as well as further clinical trials in the field of impaired fracture healing

    Framework for modulating ambulatory load in the context of in vivo mechanosensitivity of articular cartilage

    Get PDF
    Objective: Different stress modalities have been used to provoke a load induced mechanoresponse in blood markers of articular cartilages. The challenge in in vivo experiments is to alter specific loading characteristics. Here, we aimed to develop a load modification framework that changes ambulatory load magnitude without changing load frequency or joint kinematics. Design: Spatiotemporal parameters, sagittal joint kinematics and vertical ground reaction force (vGRF) of 24 healthy participants were recorded while walking with reduced (80%), normal (100%) and increased (120%) bodyweight (BW) on three separate test days in a block randomized cross-over design. The reduced and increased load conditions were compared to the normal load condition using paired sample t-tests for spatiotemporal pa- rameters and statistical parametric mapping for vGRF and joint kinematics. Results: Load modification resulted in measured vGRF differences of 19.5%BW (reduced) and þ16.8%BW (increased). Spatiotemporal parameters with reduced and increased load did not differ from normal load except of a shorter stance time under reduced load (21 ms). Joint kinematics for both conditions did not differ from normal load except of decreased ankle dorsiflexion (maximum 5.9) and increased knee flexion (maximum þ6.5) for the reduced load condition during pre-swing when the support limb is already unloaded. Conclusion: Overall, we did not observe relevant differences in spatiotemporal parameters or joint kinematics between loading conditions. Mean absolute joint angle deviations below 4.1 demonstrate that the proposed load modification framework changes ambulatory load magnitude without changing load frequency or joint kinematics

    Abductor muscle strength deficit in patients after total hip arthroplasty for hip osteoarthritis: a protocol for a systematic review and meta-analysis

    Get PDF
    Conservation of abductor muscle strength is directly associated with physical function after total hip replacement (THA). Although many studies have tried to explore and quantify a potential abductor muscle strength deficit after THA as well as identify possible causes and treatment options, this topic has not been addressed systematically.; Human-based studies reporting measurements of hip abductor strength will be included in this review. Studies reporting on hip abductor strength measured manually or isometric measurements at an abduction angle other than 0° will not be considered. No restriction will be placed on study design, publication date operative approach, prosthesis design, age and sex of the patients or severity of OA. Data sources will be Embase via embase.com, Medline ALL via Ovid and the Cochrane Central Register of Controlled Trials. The preliminary search was conducted on 5 May 2019. Data regarding absolute values or torque ratio of hip abductor torque between sides as well as patient demographic data, surgical approaches and rehabilitation protocols will be extracted. The assessment of quality and risk of bias will be performed with the modified Newcastle-Ottawa Scale. The screening, data extraction and quality assessment will be performed by two reviewers independently. Where necessary, a third review author will make a final judgement. Narrative synthesis as well as tabular presentation of the extracted data will be included. Whenever possible, metaregression and subgroup specific meta-analyses will be used to investigate the influence of time since THA and type of measurement (isokinetic or isometric) on the different outcomes. In case of sufficient information, these analyses will be extended to include characteristics such as age, sex, surgical approach or rehabilitation programme.; No ethics approval is required. The results will be disseminated through peer-reviewed publications and conference presentations.; CRD42020153185
    • …
    corecore